Evaluating Positive Pressure Ventilation in Large Structures: High-Rise Pressure Experiments(NISTIR 7412)

Evaluating Positive Pressure Ventilation in Large Structures: High-Rise Pressure Experiments(NISTIR 7412)
Author :
Publisher :
Total Pages : 82
Release :
ISBN-10 : 1494249049
ISBN-13 : 9781494249045
Rating : 4/5 (49 Downloads)

Book Synopsis Evaluating Positive Pressure Ventilation in Large Structures: High-Rise Pressure Experiments(NISTIR 7412) by : nist

Download or read book Evaluating Positive Pressure Ventilation in Large Structures: High-Rise Pressure Experiments(NISTIR 7412) written by nist and published by . This book was released on 2013-11-21 with total page 82 pages. Available in PDF, EPUB and Kindle. Book excerpt: One hundred and sixty experiments were conducted in athirty-story vacant office building in Toledo, Ohio to evaluate the ability of fire department positive pressure ventilation fans to pressurize a stairwell in a high-rise structure in accordance with established performance metrics for fixed stairwell pressurization systems. Variables such as fan size, fan angle, setback distance, number of fans, orientation of fans, number of doors open and location of vents open were varied to examine capability and optimization of each. Fan size varied from 0.4 m (16 in) to 1.2 m (46 in). Fan angle ranged from 90 degrees to 80 degrees. The setback distance went from 0.6 m (2 ft) to 3.6 m (12 ft). Between one and nine fans were used which were located at three different exterior locations and three different interior locations. Fans were oriented both inseries and in parallel configurations. Doors throughout the building were opened and closed to evaluate the effects. Finally a door to the roof and a roof hatch were used as vent points. The measurements taken during the experiments included differential pressure, air temperature, carbon monoxide, metrological data and sound levels.PPV fans utilized correctlycan increase the effectiveness of fire fighters and survivability of occupants in high-rise buildings. In a high-rise building it is possible to increase the pressure of a stairwell to prevent the infiltration of smoke if fire crews configure the fans properly. Although many factors contribute and need to be considered for effective PPV operations, properly configured PPV can achieve stairwell pressures that are high enough to meet or exceed the performance metrics for fixed smoke control systems.


Evaluating Positive Pressure Ventilation in Large Structures: High-Rise Pressure Experiments(NISTIR 7412) Related Books

Evaluating Positive Pressure Ventilation in Large Structures: High-Rise Pressure Experiments(NISTIR 7412)
Language: en
Pages: 82
Authors: nist
Categories:
Type: BOOK - Published: 2013-11-21 - Publisher:

DOWNLOAD EBOOK

One hundred and sixty experiments were conducted in athirty-story vacant office building in Toledo, Ohio to evaluate the ability of fire department positive pre
Evaluating Positive Pressure Ventilation in Large Structures
Language: en
Pages: 0
Authors: Stephen Kerber
Categories:
Type: BOOK - Published: 2007 - Publisher:

DOWNLOAD EBOOK

PPV fans utilized correctly can increase the effectiveness of fire fighters and survivability of occupants in high-rise buildings. In a high-rise building it is
Evaluating Positive Pressure Ventilation in Large Structures
Language: en
Pages: 150
Authors: nist
Categories: Architecture
Type: BOOK - Published: 2013-11-22 - Publisher: Createspace Independent Publishing Platform

DOWNLOAD EBOOK

A series of six experiments was conducted in a highrise apartment building in Chicago, Illinois. One experiment on each of the fire floors utilized portable fan
Evaluating Positive Pressure Ventilation in Large Structures
Language: en
Pages: 362
Authors: U.s. Department of Commerce
Categories: Technology & Engineering
Type: BOOK - Published: 2014-01-31 - Publisher: CreateSpace

DOWNLOAD EBOOK

A series of experiments was run in a masonry educational building examining the ability of fire service Positive Pressure Ventilation (PPV) fans to limit smoke
Evaluating Positive Pressure Ventilation in Large Structures
Language: en
Pages: 72
Authors: Stephen Kerber
Categories:
Type: BOOK - Published: 2007 - Publisher:

DOWNLOAD EBOOK

PPV fans utilized correctly can increase the effectiveness of fire fighters and survivability of occupants in high-rise buildings. In a high-rise building it is